Smart Locks & Access Controllers
Verkada AX11 IO Controller
Exact model AX11
Also identified as: AX11, AX11 IO Controller, Verkada AX11, AX11 AX11 IO Controller
Verkada AX11 is the AX11 IO Controller, sixteen-port auxiliary/elevator I/O controller for floor access, interlocks, and monitored outputs rather than ordinary door density. This exact-model guide covers published configuration, installation boundaries, operation, service, and power.
- Verkada identifies AX11 as AX11 IO Controller.
- Sixteen-port auxiliary/elevator I/O controller for floor access, interlocks, and monitored outputs rather than ordinary door density.
- Official Verkada specifications give an approximately 16.3 x 12.6 x 4.4 inch cabinet.
- Verkada AD34 multi-technology reader or AD64 keypad reader for standard controller models.
- Verkada AD34-G or AD64-G reader for the AC43-G government-grade deployment.
First time using a Scanual? Read the quick guide.
Information checked August 28, 2026. Confirm critical specifications with the manufacturer.
Official resources
Manuals and official support
Replacement parts and accessories
Products for Verkada AX11
Confirm your exact model number, the current product listing, included parts, and return terms before ordering.
Cables & connections
Network Cable
Cmple Cat 6 Ethernet Patch Cable, 5 ft
Cmple Cat 6 Ethernet Patch Cable, 5 ft is a documented-interface accessory option for Verkada AX11. Use this five-foot cable only for an indoor patch connection; it does not carry lock power unless the exact port is documented for PoE.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetwork Cable
Amazon Basics RJ45 Cat 6 Ethernet Patch Cable, 15 ft
Amazon Basics RJ45 Cat 6 Ethernet Patch Cable, 15 ft is a documented-interface accessory option for Verkada AX11. Use this fifteen-foot cable only for an indoor patch run and keep all power, pathway, and bend-radius rules for the installation.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetwork Cable
Jadaol Cat 6 Ethernet Patch Cable, 25 ft
Jadaol Cat 6 Ethernet Patch Cable, 25 ft is a documented-interface accessory option for Verkada AX11. Use this twenty-five-foot cable only where its indoor flat-cable construction and path are allowed; do not use it for outdoor or plenum runs.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetworking
TP-Link TL-SG105 5-Port Gigabit Desktop Switch
TP-Link TL-SG105 5-Port Gigabit Desktop Switch is a documented-interface accessory option for Verkada AX11. Use TL-SG105 as an upstream switch; it does not replace the controller power supply or prove PoE power compatibility.
Listing reviewed 2026-08-28
View on AmazonReport an issueAccessory
Seco-Larm SD-991A-D1Q Mini No-Cut Electric Door Strike
Seco-Larm SD-991A-D1Q Mini No-Cut Electric Door Strike is a documented-interface accessory option for Verkada AX11. Use only where the exact output mode and a separately listed 12 VDC lock-power path support the 280 mA strike load; verify fail-secure behavior, frame fit, egress, and fire-door rules.
Listing reviewed 2026-08-28
View on AmazonReport an issueAccessory
Seco-Larm SD-7101RAEX1Q Request-to-Exit Push Button
Seco-Larm SD-7101RAEX1Q Request-to-Exit Push Button is a documented-interface accessory option for Verkada AX11. Use on a documented request-to-exit input only; an access professional must preserve life-safety egress behavior and circuit supervision.
Listing reviewed 2026-08-28
View on AmazonReport an issueUpgrade options
Protection
APC Back-UPS BE600M1 600VA/330W Battery Backup and Surge Protector
APC Back-UPS BE600M1 600VA/330W Battery Backup and Surge Protector is a documented-interface accessory option for Verkada AX11. Use BE600M1 only for plug-connected upstream network gear within its load limits; it is not a replacement supply for the hardwired access cabinet.
Listing reviewed 2026-08-28
View on AmazonReport an issueProtection
Eaton Tripp Lite ULTRABLOK Isobar 2-Outlet Direct-Plug Surge Protector
Eaton Tripp Lite ULTRABLOK Isobar 2-Outlet Direct-Plug Surge Protector is a documented-interface accessory option for Verkada AX11. Use ULTRABLOK only on compatible plug-connected upstream network gear; it is surge protection, not standby power or a controller transformer.
Listing reviewed 2026-08-28
View on AmazonReport an issueModel details
Additional useful information
Use this exact-model guide for Verkada AX11 to confirm the published configuration, follow the proper installation and commissioning path, operate the controller safely, isolate common faults, and match power, wiring, sensors, readers, valves, relays, credentials, or expansion hardware without borrowing unsupported assumptions from a nearby model.
Verkada AX11 is the exact AX11 IO Controller covered here. Sixteen-port auxiliary/elevator I/O controller for floor access, interlocks, and monitored outputs rather than ordinary door density. Official Verkada specifications give an approximately 16.3 x 12.6 x 4.4 inch cabinet.
Published exact-model boundaries: Verkada AD34 multi-technology reader or AD64 keypad reader for standard controller models. Verkada EV3 multi-technology access card or official mobile NFC credential.
Setup, operation, and fault isolation: AX11 is an auxiliary and elevator I/O controller with sixteen inputs and sixteen outputs. Preserve the floor, interlock, sensor, or monitored-output purpose of every terminal and coordinate elevator wiring with the lift manufacturer. Grounding and shield treatment are especially important on traveling-cable reader runs; a relay-map error must not be mistaken for a failed floor button.
Power and service boundary for AX11: Verkada AX11 uses a fixed access-control cabinet with installer-wired input or an integral transformer/power board and documented standby-battery path. Primary power is not a removable consumer cord or wall adapter, and any SLA battery remains backup rather than a substitute for the cabinet supply.
- Verkada EV3 multi-technology access card or official mobile NFC credential.
- Verkada ACC-CEL-LTE-2 Cellular Backup Communicator where the exact controller supports chassis mounting.
- 12V or 24V electric strike or magnetic lock kept within the exact wet/dry relay limit.
- Dry-contact request-to-exit device and door-position contact using the documented inputs.
- Matched backup battery system authorized by the exact controller install guide.
- Cat 5e or Cat 6 Ethernet cable plus a line-interactive UPS for the documented AC/network input.
See something wrong? Report an error
Report a broken official link, a seller-listed item that does not match, or another factual issue. Scanual reviews requests but does not provide urgent or manufacturer support.