Smart Locks & Access Controllers
Verkada AC62 16-Door Controller
Exact model AC62
Also identified as: AC62, AC62 16-Door Controller, Verkada AC62, AC62 AC62 16-Door Controller
Verkada AC62 is the AC62 16-Door Controller, high-density sixteen-door controller with sixteen reader ports and 350W maximum system power. This exact-model guide covers published configuration, installation boundaries, operation, service, and power.
- Verkada identifies AC62 as AC62 16-Door Controller.
- High-density sixteen-door controller with sixteen reader ports and 350W maximum system power.
- The official AC62 page documents a 30 x 20 x 7 inch cabinet and lock key.
- Verkada AD34 multi-technology reader or AD64 keypad reader for standard controller models.
- Verkada AD34-G or AD64-G reader for the AC43-G government-grade deployment.
First time using a Scanual? Read the quick guide.
Information checked August 28, 2026. Confirm critical specifications with the manufacturer.
Official resources
Manuals and official support
Replacement parts and accessories
Products for Verkada AC62
Confirm your exact model number, the current product listing, included parts, and return terms before ordering.
Cables & connections
Network Cable
Cmple Cat 6 Ethernet Patch Cable, 5 ft
Cmple Cat 6 Ethernet Patch Cable, 5 ft is a documented-interface accessory option for Verkada AC62. Use this five-foot cable only for an indoor patch connection; it does not carry lock power unless the exact port is documented for PoE.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetwork Cable
Amazon Basics RJ45 Cat 6 Ethernet Patch Cable, 15 ft
Amazon Basics RJ45 Cat 6 Ethernet Patch Cable, 15 ft is a documented-interface accessory option for Verkada AC62. Use this fifteen-foot cable only for an indoor patch run and keep all power, pathway, and bend-radius rules for the installation.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetwork Cable
Jadaol Cat 6 Ethernet Patch Cable, 25 ft
Jadaol Cat 6 Ethernet Patch Cable, 25 ft is a documented-interface accessory option for Verkada AC62. Use this twenty-five-foot cable only where its indoor flat-cable construction and path are allowed; do not use it for outdoor or plenum runs.
Listing reviewed 2026-08-28
View on AmazonReport an issueNetworking
TP-Link TL-SG105 5-Port Gigabit Desktop Switch
TP-Link TL-SG105 5-Port Gigabit Desktop Switch is a documented-interface accessory option for Verkada AC62. Use TL-SG105 as an upstream switch; it does not replace the controller power supply or prove PoE power compatibility.
Listing reviewed 2026-08-28
View on AmazonReport an issueAccessory
Seco-Larm SD-991A-D1Q Mini No-Cut Electric Door Strike
Seco-Larm SD-991A-D1Q Mini No-Cut Electric Door Strike is a documented-interface accessory option for Verkada AC62. Use only where the exact output mode and a separately listed 12 VDC lock-power path support the 280 mA strike load; verify fail-secure behavior, frame fit, egress, and fire-door rules.
Listing reviewed 2026-08-28
View on AmazonReport an issueAccessory
Seco-Larm SD-7101RAEX1Q Request-to-Exit Push Button
Seco-Larm SD-7101RAEX1Q Request-to-Exit Push Button is a documented-interface accessory option for Verkada AC62. Use on a documented request-to-exit input only; an access professional must preserve life-safety egress behavior and circuit supervision.
Listing reviewed 2026-08-28
View on AmazonReport an issueUpgrade options
Protection
APC Back-UPS BE600M1 600VA/330W Battery Backup and Surge Protector
APC Back-UPS BE600M1 600VA/330W Battery Backup and Surge Protector is a documented-interface accessory option for Verkada AC62. Use BE600M1 only for plug-connected upstream network gear within its load limits; it is not a replacement supply for the hardwired access cabinet.
Listing reviewed 2026-08-28
View on AmazonReport an issueProtection
Eaton Tripp Lite ULTRABLOK Isobar 2-Outlet Direct-Plug Surge Protector
Eaton Tripp Lite ULTRABLOK Isobar 2-Outlet Direct-Plug Surge Protector is a documented-interface accessory option for Verkada AC62. Use ULTRABLOK only on compatible plug-connected upstream network gear; it is surge protection, not standby power or a controller transformer.
Listing reviewed 2026-08-28
View on AmazonReport an issueModel details
Additional useful information
Use this exact-model guide for Verkada AC62 to confirm the published configuration, follow the proper installation and commissioning path, operate the controller safely, isolate common faults, and match power, wiring, sensors, readers, valves, relays, credentials, or expansion hardware without borrowing unsupported assumptions from a nearby model.
Verkada AC62 is the exact AC62 16-Door Controller covered here. High-density sixteen-door controller with sixteen reader ports and 350W maximum system power. The official AC62 page documents a 30 x 20 x 7 inch cabinet and lock key.
Published exact-model boundaries: Cat 5e or Cat 6 Ethernet cable plus a line-interactive UPS for the documented AC/network input. Cat 5e or Cat 6 Ethernet cable plus a line-interactive UPS for the documented AC/network input.
Setup, operation, and fault isolation: AC62 is the dense sixteen-door member of the controller line, with a published 350-watt maximum system figure. Record every reader and door assignment, aggregate wet-lock demand, and the installed backup configuration before expansion. Widespread voltage or restart symptoms call for a system-budget review, while one bad opening should remain a branch-level investigation.
Power and service boundary for AC62: Verkada AC62 uses a fixed access-control cabinet with installer-wired input or an integral transformer/power board and documented standby-battery path. Primary power is not a removable consumer cord or wall adapter, and any SLA battery remains backup rather than a substitute for the cabinet supply.
- Verkada EV3 multi-technology access card or official mobile NFC credential.
- Verkada ACC-CEL-LTE-2 Cellular Backup Communicator where the exact controller supports chassis mounting.
- 12V or 24V electric strike or magnetic lock kept within the exact wet/dry relay limit.
- Dry-contact request-to-exit device and door-position contact using the documented inputs.
- Matched backup battery system authorized by the exact controller install guide.
- Cat 5e or Cat 6 Ethernet cable plus a line-interactive UPS for the documented AC/network input.